Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Chinese Journal of Behavioral Medicine and Brain Science ; (12): 349-353, 2019.
Article in Chinese | WPRIM | ID: wpr-744781

ABSTRACT

Objective To explore the influencing factors of the onset of autism spectrum disorder in male children.Methods Totally 151 male children with autism spectrum disorder were selected as case group and 119 healthy male children matched with the age of the case group in the same administrative region were taken as the control group.All children were assessed with the questionnaire for children's autism etiology and risk factors.Results (1) The differences in children having anorexia and partial eclipse (x2 =50.763,P<0.01),father's age during pregnancy (x2 =11.441,P=0.043),place of pregnancy (x2 =50.763,P<0.01),hypertension of pregnancy (x2 =5.693,P=0.026),intrauterine hypoxia (x2 =9.332,P=0.002),umbilical cord around the neck(x2 =18.483,P<0.01),parents smoking and drinking history during pregnancy (x2 =13.660,P=0.008),parental smoking (x2 =12.901,P=0.005) and alcohol consumption (x2 =8.386,P=0.039) during pregnancy,birth height of child (x2 =8.870,P=0.031),amniotic fluid pollution (x2 =4.561,P=0.043),participation time of artificial feeding,major caregivers,delayed development indicators in infants and young children and whether or not the harmonious parent-child relationship were statistically significant(P<0.05).(2) Children with anorexia and partial diet (OR =12.284,95% CI =2.768-54.507),living in rural areas during pregnancy (OR =17.251,95% CI =1.899-1 56.745),parents' history of smoking and drinking (OR =6.191,95% CI =1.678-22.838),and intrauterine hypoxia during pregnancy (OR=38.859,95%CI=2.944-512.930) may be risk factors for male autism spectrum disorder.Conclusion To correct children's anorexia bias,improve the living environment in pregnancy,reduce pregnancy complications and avoid exposure to tobacco and alcohol pollution during maternal pregnancy can be an effective entry point for the prevention and control of autism spectrum disorders in male children.

2.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 264-266,270, 2011.
Article in Chinese | WPRIM | ID: wpr-597831

ABSTRACT

Objective To summarize the technique and clinical experience of hybrid procedure under cardiopulmonary bypass (CPB) in children with muscular ventricular septal defect (mVSD). Methods From January 2006 to June 2010, 45 cases of mVSD underwent hybrid procedure with CPB. mVSDs were closed with devices under direct vision in 45 cases. Of them, there were 20 males and 25 females. They ranged from 52 days to 12 years [mean (2.05 ±2.48) year] in age and from 3 to 30 kg [(11.93 ±7.70)kg] in body weight. Preoperatively, most of children were highly susceptible to respiratory tract infections. The hybrid approach was used in all patients with CPB under the guidance of transesophageal echocardiography (TEE). The diameter of mVSDs ranged from 2 to 7 mm under TEE. Of 45 cases, 40 patients had increased rates of pulmonary blood flow. 29 patients had left axis deviation and 12 cases had sinus arrhythmia on electrocardiography (ECG). 19 had other congenital heart lesions, including transposition of great arteries in 1 case, tetralogy of Fallot in 2, pulmonary artery stenosis in 3, patent ductus arteriosus in 6, atrial septal defects in 6) and aorta coactation in 1. The quantity of VSDs were from 1 to 7 (single, in 7; two, in 24 case; three, in 8 case; four, in 5 case and seven, in lease. 37 patients were combined with pulmonary hypertension in our cohort. 38 patients with another large VSD and 19 with other congenital heart lesions were required surgical repair at sometime. Results The hybrid procedures were undertaken in all 45 cases of this cohort. All cases were successful and no deaths occurred during operation. A total of 48 devices were implanted in 45 patients, including single devices in 42 cases (device size ranged from 4 to 10 mm) and two devices in 3 cases (device size ranged from 4 -7 mm). The average time on CPB was (58.28 ±20.70) min , while aortic crossclamp time was(34. 94 ± 14.75) min. In addition, the time on mechanical ventilation postoperatively ranged from 2 hours to 6 days. Compared to the older children, 20 infante aged less than 8 monhad a significant difference in cardiac function in the early postoperative period. One infant was given up treatment because of serious infection. Anather cases recovered with the use of supportive treatment, such as using vasoactive agents, digoxin, inhaling nitric oxide, diuresis, and so on. The enteric-coated aspirin was given at dose of 5 mg ? kg -1. day -1 for a period of 3 to 6 months as usual postoperatively. All patients attended follow-up at 1 week, 1 month, 3 months, 6 months, 1 year and 2 years post-procedure. No major complications were encountered during this period. All cases were no instance of migration of any of the devices, residual shunt, aortic regurgitation, atrioventricular valve dysfunction, Ⅲo atrial-ventricular conduction block, new arrhythmia, and so on. There are no death in long-term follow-up. Conclusion Hybrid procedure is safe and effective for the closure of congenital heart defects in children.

3.
Chinese Journal of Medical Instrumentation ; (6): 33-35, 2002.
Article in Chinese | WPRIM | ID: wpr-241070

ABSTRACT

A flow controlling system for pulsed inhaled nitric oxide has been developed and tested, and here its features and initial animal experiments and clinical applications are described. The physical characteristic test indicates that the practical released dose of NO gas is very close to the theoretical flow of NO gas at variant pressures. Animal experiments demonstrate that inhaled NO gas concentration is lower than the concentration of theoretical inhalation, but the variance is not remarkable (p>0.05). When sixteen cases with CHD and PH were chosen to inhale NO gas (15 ppm, 15 min) PAP and PVR of all cases were reduced after inhalation of NO gas from 617 +/-51.3 dyn x s x cm(-5), 54.4+/-13.1 mmHg to 417+/-36.9 dym x s x cm(-5), 33.8+/-12.3 mmHg (PVR, p<0.01; PAP, p<0.01) respectively. When gas inhalation was stopped, these values returned to their base lines after a short period of time. All these show that the pulsed inhaled NO flow controlling instrument in accordance with the requirements of the designing, can be widely used in clinical diagnoses and treatments and will be a new tool offered for the treatments of the patients with PH.


Subject(s)
Animals , Child , Female , Humans , Male , Rabbits , Administration, Inhalation , Blood Pressure , Cardiac Output , Equipment Design , Heart Defects, Congenital , Therapeutics , Hypertension, Pulmonary , Therapeutics , Nebulizers and Vaporizers , Nitric Oxide , Vascular Resistance
SELECTION OF CITATIONS
SEARCH DETAIL